Accessories for correct installation
Accessories for correct installation

IS3170

NEW_EMPTY

129.40 + VAT

PCS PER PACK1

In stock

In stock

Pocket Cabur Solar stripping pliers

Pliers with fixed or exchangable inserts
Suitable for Cabur Solar Connectors, ferrules, ring and spade
Stripping pliers in pocket version for a rapid and easy operation

Additional information

Code
Type
HS code
Description
Quantity / Package
ACCESSORIES
Replacement blade
Insert
Quantity / Package (Insert)

NOTES

To ensure the guarantee’s effectiveness, the use of Cabur Solar tools, in conformance with the standards and instructions found in Cabur official documentation, is an essential requirement

For further information see PDF catalog

CB523
Fuse status signal circuit 115-230V, suitable for EFF400GR, EFF400BL, EFDS202GR,...
CB518
Fuse status signal circuit 12-48V, suitable for EFF400GR, EFF400BL, EFDS202GR,...
HF510M
Fuse status signal circuit 115-230V, suitable for HF310GR
HF518M
Fuse status signal circuit 12-48V, suitable for HF310GR
Cabur
TA5030RAM
Polyester label for equipments 50x30 mm  
Cabur
TA60100RAM
Polyester label for equipment 60x100 mm
Cabur XCSB5480W024VAA uninterruptible power supplies Capacitive Buffer
XCSB5960W024VAA
Buffer module IN: 23-30Vdc / OUT: 24Vdc 40A
Cabur XCSB5480W024VAA uninterruptible power supplies Capacitive Buffer
XCSB5480W024VAA
Buffer module IN: 23-30Vdc / OUT: 24Vdc 20A
SD200
Neutral busbars support with identification tag.
Cabur ISSD100016S
ISSD100016S
Photovoltaic circuit breakers
CABUR
DUS01
Partition plate with rail mounting, suitable for ACB.70, ACB.120, BCA.70,...
CABUR
DUS07
Partition plate with rail mounting
CABUR
DUS05
Partition plate with rail mounting, suitable for ACB.185
CABUR
DUS03
Partition plate with rail mounting, suitable for MBL.120/10, MBL150/12
Cabur ISB42CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB42CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB41CASN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB41CASN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB31CASN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB31CASN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker whitout release...
Cabur ISB21CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB21CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB22CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB22CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB11CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB11CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...

HOW TO STRIP WIRE USING IS31579002

  1. The wire stripper works like a guillotine, suitable for wires of various thicknesses, allowing for fast and safe stripping.
  2. It acts simultaneously on both the sleeves of the photovoltaic wire, cutting them precisely.
  3. The blades move parallel to the wire, expelling the sheared off sleeve.

 

STRIPPING WITH IS3170

This wire stripper is able to strip wires with sections of 2.5, 4, 6 and 10 mm2. It is fitted with an end stop and allows for a stripped constant length of approx. 8 mm, compliant with the requirements of our PINS. The blade can be replaced.

  • To strip wires with a 2.5 mm2 section, the blade must make a complete turn around the external perimeter of the wire.
  • To strip wires with a 4 mm2 section, the blade must make two complete turns around the external perimeter of the wire.
  • To strip wires with a 6 mm2 section, the blade must make three complete turns around the external perimeter of the wire.

In order to preserve the number of strands, the blade should not be turned more times than those indicated in the recommendations above for each wire section.

 

HOW TO CHANGE THE UMCT CRIMPER MATRIX

  • Open the pliers as wide as possible (fig. 1);
  • slowly bring the two levers of the pliers together, until the locking/release mechanism makes three clicks (fig. 2);
  • observe the anchorage pin on the matrix (fig. 2);
  • insert the matrix, moving the anchorage pin towards the internal part of the pliers chamber (fig.3);
  • make sure that the plastic tooth has locked the matrix in place or that it has risen (fig.4);
  • press the two levers of the pliers, closing them as tightly as possible (fig.4);
  • release the handles; the pliers should open automatically and completely (fig.5);
  • if, when the pliers are closing, you realise that thecrimping is not successful or the crimp tool is blocked for any reason, it can be released by pressing and releasing the handles a few times and simultaneously pressing with your thumb on the release lever on the
    internal part of the handle (fig.6).

IN THE SAME CATEGORY

ISCRIVITI ALLA NEWSLETTER

Name(Required)
Email(Required)
Address(Required)
Privacy(Required)
The consent to the subscription to the Cabur Newsletter can be revoked, at any time, using the unsubscribe procedure available on the emails sent. PRIVACY POLICY

CABUR CUSTOMER CARE

for technical support
+39 019 58999.219  customercare@cabur.it
for commercial support
+39 019 58999.609 vendite@cabur.it

from monday to friday 8:30-12:30 13:00-17:00