Y connectors

IS41410N

NEW

744.60 + VAT

PCS PER PACK30

In stock

In stock

Male / Female - Female Y connector

Additional information

Code
Type
HS code
TECHNICAL FEATURES
Application
Connector type
Max. applicable voltage
Max. applicable current
PIN diameter
Pliers to use
PIN material
Insulation material
Contact resistance Rc
Operating temperature range
Protection degree
Flame class
Packaging
ACCESSORIES
Open-end spanner and unlocking tool
cod. unlocking tool
Quantity / Package
Caps
Male
Female
Operating temperature range
Protection degree
Flame class
Quantity / Package
SPARE COMPONENTS
Plastic shell
Metallic PIN wound on reel
APPROVALS AND MARKINGS

NOTES

(1) IS41410N replace the code IS41410.
(2) IS42420N replace the code IS42420.

For further information see PDF catalog

CB523
Fuse status signal circuit 115-230V, suitable for EFF400GR, EFF400BL, EFDS202GR,...
CB518
Fuse status signal circuit 12-48V, suitable for EFF400GR, EFF400BL, EFDS202GR,...
HF510M
Fuse status signal circuit 115-230V, suitable for HF310GR
HF518M
Fuse status signal circuit 12-48V, suitable for HF310GR
Cabur
TA5030RAM
Polyester label for equipments 50x30 mm  
Cabur
TA60100RAM
Polyester label for equipment 60x100 mm
Cabur XCSB5480W024VAA uninterruptible power supplies Capacitive Buffer
XCSB5960W024VAA
Buffer module IN: 23-30Vdc / OUT: 24Vdc 40A
Cabur XCSB5480W024VAA uninterruptible power supplies Capacitive Buffer
XCSB5480W024VAA
Buffer module IN: 23-30Vdc / OUT: 24Vdc 20A
SD200
Neutral busbars support with identification tag.
Cabur ISSD100016S
ISSD100016S
Photovoltaic circuit breakers
CABUR
DUS01
Partition plate with rail mounting, suitable for ACB.70, ACB.120, BCA.70,...
CABUR
DUS07
Partition plate with rail mounting
CABUR
DUS05
Partition plate with rail mounting, suitable for ACB.185
CABUR
DUS03
Partition plate with rail mounting, suitable for MBL.120/10, MBL150/12
Cabur ISB42CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB42CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB41CASN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB41CASN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB31CASN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB31CASN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker whitout release...
Cabur ISB21CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB21CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB22CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB22CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB11CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB11CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...

Cabur Solar “Line 4” connectors allow simple and effective connections.
The Line 4 connectors are composed by:

  • Flying connectors, male and female
  • Panel connectors, male and female
  • Y connectors

All Cabur Solar “Line 4” connectors are supplied with caps and relative accessories.
In order to assure a connection compliance with standard, Cabur reccomend use of pliers IS3161N.
The use of this tools is mandatory for guaranteed a excelent connection and the duration of the plant.

FAST, SIMPLE, AND EFFECTIVE: CONNECTION IN JUST THREE STEPS

  1. Insert the stripped wire into the contact to be
    crimped -CRIMP IT-.
  2. Insert the wire complete with contact into the connector and push hard until you hear the typical CLICK which indicates that the plastic and metal parts are hooked together. Do not make any joints without checking that the plastic and metal parts are hooked together.
  3. Screw on the wire gland washer manually until it is firmly homed to guarantee IP67.

 

LINE 4 FLYING MALE – FEMALE CONNECTORS

The fly connectors, both male and female, are made by four main parts:

  1. Metallic PIN
  2. Rubber washer
  3. Rigid PPO plastic washer
  4. Main body made of PPO plastic
  1. Pin is a metallic contact made of tinned copper composed by two metallic wings allowing cable tightening via crimping action. The pin wings should be bending around the cable core. This action should be done with the appropriate Cabur Solar accessories.

    {%CAPTION%}
  2. Rubber washer is used to protect internal part of the connector, thus preventing penetration of external agents such as humidity, dust, and oils. This is achieved by pinching the electric wire insulating sleeve.

    {%CAPTION%}
  3. PPO plastic washer has a conical cavity that, after being screwed into the main body of the connector, forces the reeds together, compressing the rubber sheath into the wire insulation and hence acting to help ensure IP67 protection.

    {%CAPTION%}
  4. The main body holds the metallic PIN crimped onto
    the cable.

    {%CAPTION%}

Connection from male and female connectors is made having the male metallic PIN paired with the female PIN, vice versa happens for the plastic shells.
Female connector has one red rubber ring which acts as insulating washer against the penetration of external atmospheric agents.
Male and female connectors are hooked together mechanically by means of two elastic wings on the female connector which must be inserted in the male connectors insulating body special slots.

 

MALE-FEMALE PANEL CONNECTORS OF LINE 4

Fig. 5 – Esploso del corpo connettore. (il prodotto viene fornito assemblato)

The connector are made by three parts:

  1. Metallic PIN
  2. Rigid PPO hexagonal plastic washer
  3. Main body made of PPO plastic
  1. Metallic PIN is similar to the one of the flying version
  2. Hexagonal nut allows locking the connector on panel surface. Pay attention to the strength used to block the connector as, if excessive, could damage the connector.
  3. Main body made of PPO plastic is similar to the one of the flying version.

IN THE SAME CATEGORY

ISCRIVITI ALLA NEWSLETTER

Name(Required)
Email(Required)
Address(Required)
Privacy(Required)
The consent to the subscription to the Cabur Newsletter can be revoked, at any time, using the unsubscribe procedure available on the emails sent. PRIVACY POLICY

CABUR CUSTOMER CARE

for technical support
+39 019 58999.219  customercare@cabur.it
for commercial support
+39 019 58999.609 vendite@cabur.it

from monday to friday 8:30-12:30 13:00-17:00