SERIE ISM
DC stringbox with monitoring circuit

ISM0801CA10

NEW_EMPTY

6,513.00 + VAT

PCS PER PACK1

Out of stock

Out of stock

Temporarily not available for online purchase. Contact our sales department.

DC stringbox with monitoring circuit, 8 solar string inputs, 1 MPPT output, 1000 V

Up to 16 DC inputs from the Photovoltaic field
1 DC outputs to the Photovoltaic inverter
DC inputs based on Cabur Line 4 connectors
1 MPPT management
Suitable for 1000V systems
With 230 Vac release coil
With current and voltage strings monitoring
Modbus RTU comunication
With fuse holders on positive and negative circuits
CEI EN 61439-2 compliant

Additional information

Series
Code
Type
HS code
DC CIRCUIT
Number of Input (solar strings)
Number of Outputs MPPT
Max. Input Voltage
Max. Current for each string
Max. MPPT output current
Fuses
With fuse holder
Maximum rate
Type
Circuit breaker
Surge protective device
Nominal voltage Un
Protection level Up
Nominal discharge current 8/20 In
Input connection
Output connection
GENERAL DATA
Protection degree
Size (including connectors)
Standard compliancy
Data communication protocol

NOTES

(1) Our stringbox are sell without fuses, the choice of the correct size of fuse is mandatory by the customers.

For further information see PDF catalog

CB523
Fuse status signal circuit 115-230V, suitable for EFF400GR, EFF400BL, EFDS202GR,...
CB518
Fuse status signal circuit 12-48V, suitable for EFF400GR, EFF400BL, EFDS202GR,...
HF510M
Fuse status signal circuit 115-230V, suitable for HF310GR
HF518M
Fuse status signal circuit 12-48V, suitable for HF310GR
Cabur
TA5030RAM
Polyester label for equipments 50x30 mm  
Cabur
TA60100RAM
Polyester label for equipment 60x100 mm
Cabur XCSB5480W024VAA uninterruptible power supplies Capacitive Buffer
XCSB5960W024VAA
Buffer module IN: 23-30Vdc / OUT: 24Vdc 40A
Cabur XCSB5480W024VAA uninterruptible power supplies Capacitive Buffer
XCSB5480W024VAA
Buffer module IN: 23-30Vdc / OUT: 24Vdc 20A
SD200
Neutral busbars support with identification tag.
Cabur ISSD100016S
ISSD100016S
Photovoltaic circuit breakers
CABUR
DUS01
Partition plate with rail mounting, suitable for ACB.70, ACB.120, BCA.70,...
CABUR
DUS07
Partition plate with rail mounting
CABUR
DUS05
Partition plate with rail mounting, suitable for ACB.185
CABUR
DUS03
Partition plate with rail mounting, suitable for MBL.120/10, MBL150/12
Cabur ISB42CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB42CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB41CASN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB41CASN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB31CASN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB31CASN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker whitout release...
Cabur ISB21CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB21CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB22CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB22CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB11CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB11CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...

The new ISM photovoltaic panel series are suitable for monitoring the energy production of the plant in every single moment.
Thanks to the transducers is possible to monitor the string currents and the overall voltage.
Inside the panel the XCIO4 analogue converters allow to acquire the signals and information from the strings and to put them on the Modbus line.

To setup the system connection it is necessary to use the following Modbus addresses.
Default Modbus addresses:

  • • XCIO4IMB-1: STRINGS CURRENT 1-4 ID MODBUS 1
  • XCIO4IMB-2: STRINGS CURRENT 5-8 ID MODBUS 2
  • XCIO4VMB: PARALLEL VOLTAGE ID MODBUS 3

If the plant has more than one ISM panel, it will be necessary to increment the Modbus addresses of the additional devices, to avoid read conflicts (i.e. if we have a second ISM0801CA10:

ID MODBUS 3+1, ID MODBUS 3 + 2, ID MODBUS 3 + 3). The devices setup can be performed with CaburLab free software, for more information please contact our technical office.

IN THE SAME CATEGORY

ISCRIVITI ALLA NEWSLETTER

Name(Required)
Email(Required)
Address(Required)
Privacy(Required)
The consent to the subscription to the Cabur Newsletter can be revoked, at any time, using the unsubscribe procedure available on the emails sent. PRIVACY POLICY

CABUR CUSTOMER CARE

for technical support
+39 019 58999.219  customercare@cabur.it
for commercial support
+39 019 58999.609 vendite@cabur.it

from monday to friday 8:30-12:30 13:00-17:00