MCM SERIES
[blank]
CONTROL TERMINAL BOARD

MC202B

288.60 + VAT

PCS PER PACK1

In stock

In stock

control terminal board, 6mm², rear entry, white
For meters with ARON insertion
Cable entry from the rear side with 4.1 mm hole
Transparent front cover

Additional information

Series
Code
Type
HS code
Colour
TECHNICAL FEATURES
Function/Type
Rated cross-section
Rated cross-section
Connecting capacity
Flexible wire
Rigid wire
Electrical characteristics according to IEC EN standard
Maximum voltage AC/DC
Maximum current (rated cross-section)
Protection degree
Rated impulse withstand voltage / pollution degree
Insulation stripping length
Tightening torque value (nom. / max.)
Dimension
Plastic material
ACCESSORIES
Protection cover
APPROVALS AND MARKINGS

NOTES

(1) The cover is already included in the terminal board, this article is to be considered as a spare in case of need

For further information see PDF catalog

Products not found

Cabur control terminal boards have been developed in order to enable electric power suppliers and users to easily check measuring instruments, without interrupting the current carrying circuits during the verification itself or during the replacement of the instruments.

Each terminal board is composed by an insulating body, carrying the copper zinc alloy terminals to which the ammeter, voltmeter circuits and the devices for disconnect and short circuit operations are connected. Each terminal board is supplied with a transparent cover (of cellulose acetate), provided with appropriate captive screws for the sealing of the assembly.

In two-phase and three-phase terminal boards, the insulating base is built from Kelon (an abbreviation of Keramic + Nylon): this is a nylon 6 based, self-extinguishing UL94V-0 polymer with the addition of special ceramic spheres and subsequent thermal stability. The inclusion of the microspheres and the thermal procedure make the item extremely hardwearing (rigid, but also able to withstand impacts and wear and tear)

The current phases are marked in different colours, to be defined when ordering.

 

The use of MCM series control terminal boards allows:

  1. disconnection, upstream and downstream the measuring instruments
  2. the insertion of a test instrument, downstream or upstream the measuring
    instruments
  3.  shunting, by means of common plugs, from the four connection terminal
  4.  voltage transmission from the beginning of the ammeter circuit to the
    disconnect slide-link by means of a simple cross connections.

In normal service, voltmeter leads are connected to the R-S-T terminals, whilst the ammeter leads, are to be inserted in the terminals identified R1‑R2, S1-S2,
T1‑T2. The instruments are connected to terminals 1 and 2. The vertical slide‑link cross connections are closed, the horizontal slide-link
cross connections are open.

When inserting control instruments, the following instructions are to be followed:
– by means of normal plugs, the voltmeter leads must be shunted from the
test instrument on to the voltage sockets of the disconnect slide-link or to the
insertion blocks of the fuse-holders;
– the ammeter leads of the test instruments must be inserted in sockets 1 ad
R1 or 2 ad R2; same procedure is to be followed for the other phases;
– therefore, the corresponding vertical slide-link must be disconnected.

If there is a need to replace a measuring instrument, it is necessary to
previously close the horizontal slide-links, disconnect the vertical slide-links and
open the slide-link.

Feeding conductors (incoming and outcoming) are inserted from the rear of the
terminal board, with conductors passing through slots on the insulating base of
the terminal board

IN THE SAME CATEGORY

Multi-polar cross connections “Easy Bridge Plus” for CBC.6 terminal block
Industrial connectivity solutions

Multi-polar cross connections “Easy Bridge Plus” for CBC.6 terminal block

The new “Easy Bridge Plus” multi-pole cross connections for CBC.6 terminal blocks are available in red or blue colours for instant visibility. If needed, the upper surface can be marked with a permanent marker to highlight the presence of the pole and of the electrical connection with the underlying terminal block in pole skipping cross connection configurations.

READ MORE »

ISCRIVITI ALLA NEWSLETTER

Name(Required)
Email(Required)
Address(Required)
Privacy(Required)
The consent to the subscription to the Cabur Newsletter can be revoked, at any time, using the unsubscribe procedure available on the emails sent. PRIVACY POLICY

CABUR CUSTOMER CARE

for technical support
+39 019 58999.219  customercare@cabur.it
for commercial support
+39 019 58999.609 vendite@cabur.it

from monday to friday 8:30-12:30 13:00-17:00