MCT/SA SERIES
[blank]
CONTROL TERMINAL BOARD

MC402R

386.00 + VAT

PCS PER PACK1

In stock

In stock

control terminal board, 6mm², side entry, red
For meters with ARON insertion
Side cable entry with 8 mm wide slot
Transparent front cover

Additional information

Series
Code
Type
HS code
Colour
TECHNICAL FEATURES
Function/Type
Rated cross-section
Rated cross-section
Connecting capacity
Flexible wire
Rigid wire
Electrical characteristics according to IEC EN standard
Maximum voltage AC/DC
Maximum current (rated cross-section)
Protection degree
Rated impulse withstand voltage / pollution degree
Insulation stripping length
Tightening torque value (nom. / max.)
Dimension
Plastic material
ACCESSORIES
Protection cover
APPROVALS AND MARKINGS

NOTES

For further information see PDF catalog

CB523
Fuse status signal circuit 115-230V, suitable for EFF400GR, EFF400BL, EFDS202GR,...
CB518
Fuse status signal circuit 12-48V, suitable for EFF400GR, EFF400BL, EFDS202GR,...
HF510M
Fuse status signal circuit 115-230V, suitable for HF310GR
HF518M
Fuse status signal circuit 12-48V, suitable for HF310GR
Cabur
TA5030RAM
Polyester label for equipments 50x30 mm  
Cabur
TA60100RAM
Polyester label for equipment 60x100 mm
Cabur XCSB5480W024VAA uninterruptible power supplies Capacitive Buffer
XCSB5960W024VAA
Buffer module IN: 23-30Vdc / OUT: 24Vdc 40A
Cabur XCSB5480W024VAA uninterruptible power supplies Capacitive Buffer
XCSB5480W024VAA
Buffer module IN: 23-30Vdc / OUT: 24Vdc 20A
SD200
Neutral busbars support with identification tag.
Cabur ISSD100016S
ISSD100016S
Photovoltaic circuit breakers
CABUR
DUS01
Partition plate with rail mounting, suitable for ACB.70, ACB.120, BCA.70,...
CABUR
DUS07
Partition plate with rail mounting
CABUR
DUS05
Partition plate with rail mounting, suitable for ACB.185
CABUR
DUS03
Partition plate with rail mounting, suitable for MBL.120/10, MBL150/12
Cabur ISB42CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB42CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB41CASN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB41CASN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB31CASN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB31CASN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker whitout release...
Cabur ISB21CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB21CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB22CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB22CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...
Cabur ISB11CANN00001 DC photovoltaic stringboxes with thermal magnetic circuit breaker and release coil SERIE ISB
ISB11CANN00001
DC photovoltaic stringbox with thermal magnetic circuit breaker without release...

Cabur control terminal boards have been developed in order to enable electric power suppliers and users to easily check measuring instruments, without interrupting the current carrying circuits during the verification itself or during the replacement of the instruments.

Each terminal board is composed by an insulating body, carrying the copper zinc alloy terminals to which the ammeter, voltmeter circuits and the devices for disconnect and short circuit operations are connected. Each terminal board is supplied with a transparent cover (of cellulose acetate), provided with appropriate captive screws for the sealing of the assembly.

In two-phase and three-phase terminal boards, the insulating base is built from Kelon (an abbreviation of Keramic + Nylon): this is a nylon 6 based, self-extinguishing UL94V-0 polymer with the addition of special ceramic spheres and subsequent thermal stability. The inclusion of the microspheres and the thermal procedure make the item extremely hardwearing (rigid, but also able to withstand impacts and wear and tear)

The current phases are marked in different colours, to be defined when ordering.

 

The use of MCM series control terminal boards allows:

  1. disconnection, upstream and downstream the measuring instruments
  2. the insertion of a test instrument, downstream or upstream the measuring
    instruments
  3.  shunting, by means of common plugs, from the four connection terminal
  4.  voltage transmission from the beginning of the ammeter circuit to the
    disconnect slide-link by means of a simple cross connections.

In normal service, voltmeter leads are connected to the R-S-T terminals, whilst the ammeter leads, are to be inserted in the terminals identified R1‑R2, S1-S2,
T1‑T2. The instruments are connected to terminals 1 and 2. The vertical slide‑link cross connections are closed, the horizontal slide-link
cross connections are open.

When inserting control instruments, the following instructions are to be followed:
– by means of normal plugs, the voltmeter leads must be shunted from the
test instrument on to the voltage sockets of the disconnect slide-link or to the
insertion blocks of the fuse-holders;
– the ammeter leads of the test instruments must be inserted in sockets 1 ad
R1 or 2 ad R2; same procedure is to be followed for the other phases;
– therefore, the corresponding vertical slide-link must be disconnected.

If there is a need to replace a measuring instrument, it is necessary to
previously close the horizontal slide-links, disconnect the vertical slide-links and
open the slide-link.

Feeding conductors (incoming and outcoming) are inserted from the rear of the
terminal board, with conductors passing through slots on the insulating base of
the terminal board

IN THE SAME CATEGORY

Multi-polar cross connections “Easy Bridge Plus” for CBC.6 terminal block
Industrial connectivity solutions

Multi-polar cross connections “Easy Bridge Plus” for CBC.6 terminal block

The new “Easy Bridge Plus” multi-pole cross connections for CBC.6 terminal blocks are available in red or blue colours for instant visibility. If needed, the upper surface can be marked with a permanent marker to highlight the presence of the pole and of the electrical connection with the underlying terminal block in pole skipping cross connection configurations.

READ MORE »

ISCRIVITI ALLA NEWSLETTER

Name(Required)
Email(Required)
Address(Required)
Privacy(Required)
The consent to the subscription to the Cabur Newsletter can be revoked, at any time, using the unsubscribe procedure available on the emails sent. PRIVACY POLICY

CABUR CUSTOMER CARE

for technical support
+39 019 58999.219  customercare@cabur.it
for commercial support
+39 019 58999.609 vendite@cabur.it

from monday to friday 8:30-12:30 13:00-17:00