Programmable galvanic isolator
Analogue signal converters

X756516

492.00 + VAT

PCS PER PACK1

Out of stock

Out of stock

Temporarily not available for online purchase. Contact our sales department.
PRODOTTO REPLACED BY XCONAA516P

Analog signal converters IN: 14 or 16 selactable ranges / OUT: 3 ranges

Input: 14 or 16 selactable ranges
Output: 3 selectable ranges
3-way isolation

Additional information

Series
Code
Type
HS code
INPUT TECHNICAL DATA
Signal type IN
Input range IN
Input impedance IN
Parametrization IN
OUTPUT TECHNICAL DATA
Signal type OUT
Output range OUT
Maximum output signal OUT
Load impedance OUT
Ripple
Status indication
Parametrization OUT
GENERAL TECHNICAL DATA
Power supply voltage
Current consumption
Accuracy
Linearity error
Temperature coefficient
Transmission frequency
Rise time
Operating temperature range
Insulation
Insulation type
Overvoltage category / pollution degree
Protection degree
Connection terminal IN / OUT
Housing material
Dimensions (LxHxD)
Approximate weight
Mounting information
ACCESSORIES
Mounting rail (IEC60715/TH35-7.5)
Marking tag
APPROVALS AND MARKINGS

NOTES

For further information see PDF catalog

Cabur
BT003
End bracket for rail type TH35, suitable for NU1051S, NU0851S,...
Cabur BT007 END BRACKETS BT SERIES
BT007
End bracket for rail type TH35, suitable for NU1051S, NU0851S,...
Cabur BT003 END BRACKETS BT SERIES
BT005
End bracket for rail type G32 and TH35, suitable for...
CABUR PR003 MOUNTING RAILS PR SERIES
PR905
Mounting rail TH35-7,5 with holes
CABUR PR003 MOUNTING RAILS PR SERIES
PR005
Mounting rail TH35-7,5 with holes
CABUR PR003 MOUNTING RAILS PR SERIES
PR903
Mounting rail TH35-7,5
CABUR PR003 MOUNTING RAILS PR SERIES
PR003
Mounting rail TH35-7,5
Cabur TAP179W
TAP128AW
PVC adhesive tag, 8x12mm, White
Cabur TAP179W
TAP128AY
PVC adhesive tag, 8x12mm, Yellow

Applications of analogue converters and galvanic separation

They convert electrical signals generated by sensors which take physical measure-ments such as temperature (thermocouples and PT100 resistance thermometers), frequency (proximity, contacts, photocells), current (TA, Hall sensors), resistance (potentiometers), voltage, pressure, level, etc. into standardised electrical signals, adapting them to PLC, DCS and industrial PC (control) outputs, or they convert a given analogue signal into a different one, adapting it to control inputs/outputs or allowing for long-distance signal transmission without interference by means of galvanic separation (fig. 1).

Adaptation between sensor output signal and control input signal

Long-distance signal transmission
Voltage signals can reach a max. distance of 10-20 m, beyond which they lose reliability and become highly sensitive to induced and ground-derived interference, therefore in order to transmit to distances beyond 20 m a voltage signal must be converted into a current signal and galvanically separated (fig. 2).
Current signals can surpass a transmission distance of 300 m and are less sensitive to induced interference. The long-distance transmission of a current signal requires galvanic separation.

Galvanic signal separation (signal isolation):

  • isolates and electrically separates the sensor circuit from the control circuit and from the power supply circuit; each circuit therefore operates in relation to its own zero potential which, being isolated from other circuits, cannot be altered by ever-present potential differences between different ground references (fig.3)

  • isolates and separates different ground potentials between power supply, control and sensors/actuators
  • allows for signal transmission without errors or interference and with greater reliability
  • the higher the isolation (in kV), the greater the security of the transmission in the presence of ground potentials, electromagnetic or temporary interference (light-ning, discharge, etc.). (fig 4)

Galvanic separation is necessary when:

  • the distance between control and sensor/actuator is greater than 20 m
  • ground or mass references are different
  • ground potentials are high, or may become high in case of discharges or currents leaked to ground
  • electromagnetic interference is present
  • signal cables are wired in ducts with power cables (fig. 5)

Connection of analogue converters in series and in parallel

  • To obtain signal redundancy or to simply duplicate it, multiple converter inputs can be connected to a single sensor.
  • In case of current signals, the converter input will be connected in series (fig. 6)
  • In case of voltage signals, the converter input will be connected in parallel (fig. 7

IN THE SAME CATEGORY

ISCRIVITI ALLA NEWSLETTER

Name(Required)
Email(Required)
Address(Required)
Privacy(Required)
The consent to the subscription to the Cabur Newsletter can be revoked, at any time, using the unsubscribe procedure available on the emails sent. PRIVACY POLICY

CABUR CUSTOMER CARE

for technical support
+39 019 58999.219  customercare@cabur.it
for commercial support
+39 019 58999.609 vendite@cabur.it

from monday to friday 8:30-12:30 13:00-17:00